dc.description.abstract |
The biomechanical rationale and review various options for fixation of
fractures of the shaft clavicle were examined using different fixation constructs
a flat plate extramedullary, intramedullary screw, double derotation plate
derotation plates with lugs. Deformability biomechanical system in cases of
simple and complex type of deformation were determined by theoretical and
experimental ways |